Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer (1119-1401)

Atomic Absorption Spectrophotometer is applied to micro and trace metallic elements test, covering over 30 elements. The instrument has simple structure, provides fast test, with good repeatability and less interference, especially suitable for testing Cu, Zn, K, Na, Au, Ag, etc.

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer (1119-1401)

Atomic Absorption Spectrophotometer is applied to micro and trace metallic elements test, covering over 30 elements. The instrument has simple structure, provides fast test, with good repeatability and less interference, especially suitable for testing Cu, Zn, K, Na, Au, Ag, etc.

Features:

Features:

  • Build-in computer data processing and LCD display.
  • Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.
  • Quickly: The cathode lamp does not need to be pre-heated for long time and sample can be analysed immediately.
  • High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
  • High energy optical path.
  • Long-life and anti-corrosive atomization system.
  • Multi-functional analysis mode:
  • Flame absorption
  • Flame emission
  • Graphite Furnace Atomic Absorption
  • Hydride Generation.
  • Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.

Specifications

Specifications

Model

1119-1401

Wavelength Range

190-900nm

Wavelength Accuracy

≤ ±0.5nm

Wavelength Repeatability

≤ 0.3nm (single direction)

Spectral Bandwidth

0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

Grating

1800 lines/mm

Resolution

<40%

Base Line Stability

±0.004Abs/30min

Characteristic Concentration

≤ 0.04mg/ml/1% (Cu)

Detection Limit of Copper

≤0.008mg/ml (Cu)

Background Calibration Ability

Greater than 30 times

Power Supply

220V, 50/60Hz

Packing Size(mm)

1250 x 795 x 765 (Main instrument), 545 x 445 x 1385 ( Accessories )

Gross Weight(kg)

138Kg (Main instrument), 56Kg ( Accessories)

Standard Accessories

RS232 serial port
Oil-free air compressor
Glass Atomizer
Cu Hollow cathode lamp
Atomizer unit, Burner unit ,Dust cover
Water-separating gas filter
Titanium burner---10cm

Optional Accessories

Model 1119-3202 Graphite Furnace System
Hydride generator
Graphite tubes
Software
Recirculating cooling water system
Printer
Hollow cathode lamp (Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K,
AU, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc)

 

Accessories

Accessories

Graphite Furnace System

1119-3202

  • Heating steps: 9 steps
  • Temperature range (nominal Temperature): 20°C~3000°C
  • Slope heating time: 0~999s
  • Heating holding time: 1s~999s (the sum of both time should be less than 999 seconds)
  • Inert gas needed: argon, pressure of entry larger than 0.3Mpa
  • Cooling water: tap water or cycling water, flow rate no lessthan 2L/min
  • Output: LCD
  • Gas pressure alarm, furnace overheated alarm
  • Interface with Atomic Absorption  Spectrophotometer, autosampler and RS232
  • High-power temperature heating function (1000°C~2700°C)
  • Test sample together with atom absorption equipment.Cd ≤1×10-12g;Cu ≤1×10-10g
  • Working Conditions:
  • Power source: 220V±22V, 50Hz±1Hz, 3A
  • 220V±22V, 50Hz±1Hz, 30A
  • Power: 5.1kW for 220V on about 2700°C
  • Ambient temperature: +10°C~+30°C
  • Relative humidity: less than 85%
  • Instrument rating power: 7.2kW

Chiller Circulation

1119-800

It is an important optional accessory for supporting Atomic Absorption Spectrophotometer and Graphite Furnace

  • Nominal cooling capacity: 800W
  • Temperature control range: 5 ~ 35 (°C)
  • Temperature control accuracy: ± 0.1 (°C)
  • Pump head (max./rated): 10/8 (m)
  • Flow (Max / Rated): 15/6 (L / min)
  • Water tank volume: 15L
  • Power Supply: AC220V / 50Hz
  • Instrument Size: 330mm × 500mm × 500 mm

Hydride Generator

1119-1021

Hydride Generator is used with Atomic Absorption Spectrophotometer

Features :

  • Measurement Method : Continuous Flow Injection
  • Reducing Agent: NaBH4
  • Sample Feed Rate: 0~ 7mL / min
  • Reagent Feed Rate 0 ~ 2.5mL / min
  • Burning Head : Heating Quartz Tube (Heating with acetylene combustion
  • Carrier Gas Ar, Supply Pressure0.32MPa
  • Power Supply: AC220V / 50Hz / 30W
  • Instrument Size: 290×220×208mm

Autosampler

1119-4020

The autosampler is an important optional accessory to improve the technical indicators and automation of the Atomic Absorption Spectrophotometer.
Under the control of the graphite furnace system, standard solutions can be prepared automatically. It can be automatic sample pre concentration & dilution, and automatically add matrix improver, automatic cleaning and other functions.

Features :

  • Number of sample cups: 95
  • Sample cup capacity: 1.5mL
  • Number of reagent cups: 5
  • Reagent cup capacity: 5mL
  • Injection volume: 1 ~ 95μL (1μL increment)
  • Injection volume accuracy: ± 2% (20μL)
  • Injection volume precision: ≤1% (20μL)