
Dia of Sterilization Chamber : The heavy-gauge sterilization chamber in a diameter of 40cm offers a massive space to satisfy various sterilization requirements.
Microcomputer Control System : “Inspiration” fast speed Microcomputer intelligent control system is highly robust to not only realize the total-process controls of sterilization, but also enable convenient maintenance, inquiry, calibration ,recording and upward scalability in the future. It allows three tiers of administrations, i.e. user, user administrator and engineer, to guarantee satisfactory use and management of autoclave.
Waste Sterilization Mode : dedicated waste sterilization procedures are established for effective sterilization of lab wastes.
Drying Function : Thoroughly drying according to CE standards
Cooling Lock Open Temperature : Each procedure can set different cooling lock open temperatures according to the thermal inertia of the sterilization object so as to prevent the user from opening the cover and hence getting burnt when the sterilization object (particularly liquid object) is still in an unsafe state.
Sterilization Temperature : 105°C -138°C
Function :
Mechanical Interlocking : The unique “eight-column evenly distributed” interlocking device is safer and more reliable than common interlocking devices.
Electric Double Inner Locks : Enable the control system to monitor the temperature and pressure in the sterilization chamber on areal-time basis and disable opening of the sterilization chamber cover until the safe temperature and pressure are reached, hence guaranteeing the personal safety of the operator.
Six Preset Procedures : Six sterilization procedures and warming procedures are preset for the sterilizing, warming and drying of solids and liquids, the melting and warming of agars.
Agar processing : It can heat and melt down and preserve heat of agars or preheat the sterilization chamber.
Timed startup : It is possible to preset a time program so that the autoclave can be automatically started for sterilization according to the preset schedule.
Memory system : The operator can set the sterilization parameters and create as many as 60 procedures that can be readily used.
Steam discharge control : Upon completion of sterilization procedure, the vent valve can automatically open to discharge steams at the preset temperature.
Calibration interface : Temperature and pressure calibration interfaces are available for calibration purpose.
Automatic water feeding : Exempt the convenience of frequent water feeding; water level sensors are installed to automatically stop the autoclave and give out alarms when water is running out.
Saturated Steam Monitoring : The system can automatically monitor the discharge conditions of cold air so as to guarantee a sterilizing environment of pure steams and optimal sterilization effects.
Model No. |
518060 |
518110 |
Capacity |
60 Litres |
110 Litres |
Dimensions (L x W x H) in mm |
660 x 644 x 980 |
660 x 644 x 1180 |
Sterilization Chamber Dimension (Dia X H) in mm |
Φ 400 × 505 |
Φ 400 × 895 |
Working Environment |
5°C ~ 40°C Relative Humidity 10% to 85% | |
Sterilization Chamber Material |
SUS 304 | |
Sterilization Temperature |
105°C ~ 138°C | |
Preset Range of Sterilization Time |
1 to 300 Minutes | |
Preset Range of Melting Temperature |
60°C to 100°C | |
Preset Range of Melting Time |
1 to 300 Minutes | |
Preset Range of Warming Temperature |
45°C to 60°C | |
Preset Range of Warming Time |
1 to 9999 Minutes | |
Preset Range of Drying time |
1 to 300 Minutes | |
Preset Range of Cooling Lock Open Temperature |
40°C to 99°C for Solid and Agar Modes and 40°C to 80°C for Liquid and Waste Modes | |
Preset Range of Steam Exhausting Temperature |
73°C to 104°C | |
Exhausting Mode |
Fully Automatic Internal Discharging embedded with a Steam trapping bottle | |
Preset Range of Timer |
0 Minutes - 6 days Delayed | |
Range of Pressure Guage |
0 to 0.6Mpa | |
Rated Working Pressure |
0.27Mpa | |
Controller |
"Inspiration" Fast-Speed Microcomputer Intelligent Control System | |
Rated Power Supply |
220V 50Hz/60Hz | |
Rated Power |
2900W |
4600W |
Safety Device |
"Eight Column Evenly Distributed" Interlocking Device, Electric Double Inner Locks, Dry Scorch Protection, Over Pressure Protection, Safety Valve, Over Temperature Protection, Over current and Short Circuit Protection, Leakage Protection, Cooling Lock, Anti-scald Chamber Cover and Bench, Automatic Trouble Shooting | |
Accessories |
Stainless Steel Basket |
|
Optional Accessories |
Printer, Cooling Fan, Load Thermometer |